Misfit of Morse taper implant joints
| dc.contributor.advisor | Gavinha, Sandra | |
| dc.contributor.author | Souza, Júlio César Matias de | |
| dc.date.accessioned | 2013-03-21T08:49:55Z | |
| dc.date.available | 2013-03-21T08:49:55Z | |
| dc.date.issued | 2012 | |
| dc.description | Projeto de Pós-Graduação/Dissertação apresentado à Universidade Fernando Pessoa como parte dos requisitos para obtenção do grau de Mestre em Medicina Dentária | por |
| dc.description.abstract | Falhas em sistemas de implantes dentários causadas pelo acúmulo de biofilmes, inflamação peri-implantar e degradação de materiais tem sido associadas ao desajuste de conexões entre pilares protéticos e implantes dentários. Sendo assim, o objetivo desse estudo foi caracterizar o ajuste implante-pilar de um sistema do tipo cone Morse por técnicas microscópicas. Um grupo de dez implantes e respectivos minipilares protéticos foram estudados. Superfícies da área das conexões dos implantes e dos minipilares protéticos foram inspecionadas por microscopia eletrônica de varrimento (MEV). Em seguida, os componentes foram conectados sob torque de 32 Ncm e embutidos em resina epóxica. As amostras implante-minipilar foram então seccionadas perpendicularmente ao plano da conexão implante-minipilar para mensuração das microfendas por MEV. Além disso, as áreas inspecionadas por MEV foram também analisadas quanto a composição química por espectroscopia de energia dispersiva (EDS) assim como por testes de nanoindentação e microdureza de Vickers. Defeitos originados do processamento foram detectados em todos as superfícies dos minipilares analisados por MEV. Os valores das dimensões das microfendas entre implante e minipilar variaram de 0,5 a 5 μm, aproximadamente. A presença de defeitos nas áreas de conexão intensificou a discrepância das microfendas. Os elementos Ti, Al e V foram identificados no espectro obtido por EDS dos minipilares o que sugere a composição da liga Ti6Al4V. Já para os implantes, apenas o elemento Ti foi identificado, o que confirma a sua composição baseada em titânio comercialmente puro. Maiores valores de microdureza Vickers foram encontrados para o pilar protético de Ti6Al4V (360 ± 17 HV) quando comparados aos valores para os implante de Ti CP (320 ± 8 HV). A diferença entre os valores de dureza do minipilar e implante dentário pode acelerar o processo de desgaste das conexões sob mcromovimentos durante a mastigação e aumentar as dimensões das microfendas. A adaptação pilar-implante pode ser alterada pelos defeitos aumentando assim tamanho dos microgaps e consequentemente facilitando o acúmulo de biofilmes e fluidos orais. Failures in dental implants systems caused by biofilm accumulation, peri-implant inflammation and material degradation have been correlated to the misfit of implantabutment joints. The main aim of this study was to characterize the fit of Morse Taper implant-abutment joints by microscopic analyses. Surfaces of 10 Morse taper implant systems were inspected by scanning electron microscopy (SEM) before connection. After initial inspection, the implant-abutment systems were connected by applying a torque of 32 Ncm. For microgaps measurements by SEM, implant-abutment assemblies were embedded in epoxy resin and cross-sectioned at a perpendicular plane of the implant-abutment joint. Also, microhardness, nanoindentation and chemical analyses were performed at the implant-abutment joints. Concerning surfaces, defects originated from industrial processing were noticed on different areas of the abutment surfaces. On implant-abutment misfit measurements, the size of microgaps ranged from 0.5 μm up to 5.6 μm. Defects were also detected at implant-abutment microgaps that can increase the microgap size after connection. Microhardness tests revealed a higher hardness (360 ± 17 HV) for Ti6Al4V-based abutment when compared to implant composed of commercially pure titanium (320 ± 8 HV). The mismatch in mechanical properties between abutment and implant can increase the degradation of structural materials under micro-movements during mastication affecting the implant-abutment misfit and mechanical integrity of the implant-abutment joints during mastication. Defects on surfaces of abutments can intensify misfit of Morse taper implant joints. That might allow the penetration of oral microorganisms and fluids. | por |
| dc.identifier.uri | http://hdl.handle.net/10284/3715 | |
| dc.language.iso | eng | por |
| dc.publisher | [s.n.] | por |
| dc.subject | Implantes dentários | por |
| dc.subject | Minipilares protéticos | por |
| dc.subject | Microfendas | por |
| dc.subject | Desajuste | por |
| dc.subject | Cone morse | por |
| dc.subject | Dental implants | por |
| dc.subject | Abutment | por |
| dc.subject | Morse taper | por |
| dc.subject | Misfit | por |
| dc.subject | Characterization | por |
| dc.title | Misfit of Morse taper implant joints | por |
| dc.type | master thesis | |
| dspace.entity.type | Publication | |
| rcaap.rights | openAccess | por |
| rcaap.type | masterThesis | por |
Ficheiros
Principais
1 - 1 de 1
Miniatura indisponível
- Nome:
- Julio César Matias de Souza_Master Thesis_16-7.pdf
- Tamanho:
- 4.25 MB
- Formato:
- Adobe Portable Document Format
Licença
1 - 1 de 1
Miniatura indisponível
- Nome:
- license.txt
- Tamanho:
- 1.71 KB
- Formato:
- Item-specific license agreed upon to submission
- Descrição: