Publicação
Concordância interobservador e fiabilidade da avaliação do padrão respiratório de forma remota em pessoas com doença pulmonar obstrutiva crónica
| dc.contributor.advisor | Vilarinho, Rui | |
| dc.contributor.author | Freitas, Pedro Rafael da Silva | |
| dc.date.accessioned | 2026-01-27T11:07:07Z | |
| dc.date.available | 2026-01-27T11:07:07Z | |
| dc.date.issued | 2025 | |
| dc.description | Projeto de Graduação apresentado à Universidade Fernando Pessoa como parte dos requisitos para obtenção do grau de Licenciado em Fisioterapia. | |
| dc.description.abstract | Introdução: A avaliação do padrão respiratório é essencial na gestão da doença pulmonar obstrutiva crónica (DPOC). Este estudo avaliou a fiabilidade interobservador do Breathing Pattern Assessment Tool (BPAT), aplicado presencialmente e remotamente, por vídeo. Métodos: Participaram 18 pessoas com DPOC (72% mulheres; média 80 anos). O BPAT foi aplicado por quatro avaliadores um presencial e três remotos com base em vídeos. A concordância foi analisada pelo coeficiente de correlação intraclasse (CCI) e o teste de Friedman avaliou diferenças entre pontuações. Resultados: O BPAT obteve CCI total de 0,70 (suficiente). Itens como fluxo expiratório (CCI=0,88) e via respiratória (CCI=0,84) revelaram alta concordância. Movimento, ritmo e fome de ar tiveram menor consistência (CCI≈0,32–0,38). O teste de Friedman indicou ausência de diferenças estatisticamente significativas (p=0,245). Conclusão: O BPAT demonstrou fiabilidade suficiente na avaliação remota do padrão respiratório em pessoas com DPOC, destacando-se como um instrumento com aplicabilidade em contextos de teleconsulta. | por |
| dc.description.abstract | Introduction: Respiratory pattern assessment is essential in the management of Chronic Obstructive Pulmonary Disease (COPD). This study evaluated the inter-rater reliability of the BPAT, applied both in person and remotely via video. Methods: Eighteen individuals with COPD participated (72% women; mean age 80 years). The BPAT was applied by four raters (one in-person, three remote) using recorded videos. Inter-rater agreement was assessed using the Intraclass Correlation Coefficient (ICC), and the Friedman test was used to evaluate differences between scores. Results: The BPAT showed an overall intraclass correlation coefficient (ICC) of 0.70 (considered sufficient). Items such as expiratory flow (ICC=0.88) and respiratory route (ICC=0.84) demonstrated high agreement. Movement, rhythm, and air hunger showed lower consistency (ICC≈0.32–0.38). Inspiratory flow had an undefined ICC in remote assessment. The Friedman test indicated no statistically significant differences between assessment conditions (p=0.245). Conclusion: The BPAT showed moderate reliability in the remote assessment of respiratory pattern in people with COPD, supporting its usefulness in teleconsultation settings. | eng |
| dc.identifier.uri | http://hdl.handle.net/10284/14922 | |
| dc.language.iso | por | |
| dc.peerreviewed | n/a | |
| dc.publisher | [s.n.] | |
| dc.rights.uri | http://creativecommons.org/licenses/by/4.0/ | |
| dc.subject | DPOC | |
| dc.subject | Padrão respiratório | |
| dc.subject | Avaliação remota | |
| dc.subject | BPAT | |
| dc.subject | COPD | |
| dc.subject | Breathing pattern | |
| dc.subject | Remote assessment | |
| dc.title | Concordância interobservador e fiabilidade da avaliação do padrão respiratório de forma remota em pessoas com doença pulmonar obstrutiva crónica | por |
| dc.type | bachelor thesis | |
| dspace.entity.type | Publication | |
| oaire.version | http://purl.org/coar/version/c_b1a7d7d4d402bcce |
