Repository logo
 
Publication

Indoor air quality and sustainability management — case study in three portuguese healthcare units

dc.contributor.authorFonseca, Ana
dc.contributor.authorAbreu, Isabel
dc.contributor.authorGuerreiro, Maria
dc.contributor.authorAbreu, Cristina
dc.contributor.authorSilva, Ricardo
dc.contributor.authorBarros, Nelson
dc.date.accessioned2019-10-28T12:36:09Z
dc.date.available2019-10-28T12:36:09Z
dc.date.issued2018-12-25
dc.description.abstractAdequate management of indoor air quality (IAQ) in healthcare units has relevant impacts on sustainability performance due to its effects on patient safety, occupational health and safety, and energy consumptions. This study sought to identify improvement opportunities on IAQ management by collecting and analyzing experimental data of selected parameters in three healthcare units in Portugal: Two general hospitals and one primary healthcare center. Indoor air temperature, relative humidity, CO2, bacteria, and fungi concentrations were measured in summer and winter campaigns in June/July 2017 and in January/March 2018. Results show that the exclusive use of natural ventilation is not adequate when the affluence of users is high, but the analyzed parameters revealed acceptable results under low occupation intensity conditions. Results also show that keeping low indoor air relative humidity has a significant impact in reducing fungi concentration and that there is a significant correlation at the 0.05 level between indoor air CO2 concentration and bacterial loads. Therefore, as opportunities to improve sustainability, IAQ management in healthcare facilities should consider natural ventilation as a complement to mechanical ventilation systems and should focus on adequate control of indoor air relative humidity and CO2 concentration to reduce the risk of airborne infections.pt_PT
dc.description.versioninfo:eu-repo/semantics/publishedVersionpt_PT
dc.identifier.doi10.3390/su11010101pt_PT
dc.identifier.issn1937-0695
dc.identifier.urihttp://hdl.handle.net/10284/8183
dc.language.isoengpt_PT
dc.peerreviewedyespt_PT
dc.publisherMDPIpt_PT
dc.relationUID/Multi/04546/2016pt_PT
dc.relation.publisherversionhttps://www.mdpi.com/2071-1050/11/1/101pt_PT
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/pt_PT
dc.subjectIndoor air qualitypt_PT
dc.subjectHealthcare facilitiespt_PT
dc.subjectSustainability managementpt_PT
dc.titleIndoor air quality and sustainability management — case study in three portuguese healthcare unitspt_PT
dc.typejournal article
dspace.entity.typePublication
oaire.citation.issue1pt_PT
oaire.citation.titleSustainabilitypt_PT
oaire.citation.volume11pt_PT
person.familyNameFonseca
person.familyNameCunha de Abreu
person.familyNameGuerreiro
person.familyNameAbreu
person.familyNameSilva
person.familyNameAugusto Cruz de Azevedo Barros
person.givenNameAna
person.givenNameIsabel Maria
person.givenNameMaria
person.givenNameCristina
person.givenNameRicardo
person.givenNameNelson
person.identifier560773
person.identifier.ciencia-idF61F-23C0-BBF5
person.identifier.ciencia-id3C1D-1BE9-8494
person.identifier.ciencia-id1216-4260-3FD7
person.identifier.ciencia-idBA1E-FA67-80E5
person.identifier.ciencia-id2919-FCDB-B684
person.identifier.orcid0000-0002-3207-4819
person.identifier.orcid0000-0001-5274-4536
person.identifier.orcid0000-0001-6774-9348
person.identifier.orcid0000-0002-9289-1562
person.identifier.orcid0000-0002-7276-4435
person.identifier.orcid0000-0002-2628-9880
person.identifier.ridG-5355-2013
person.identifier.ridK-5451-2012
person.identifier.scopus-author-id7101964374
person.identifier.scopus-author-id55582858000
person.identifier.scopus-author-id23024471700
person.identifier.scopus-author-id7201604712
rcaap.rightsopenAccesspt_PT
rcaap.typearticlept_PT
relation.isAuthorOfPublication1f238a52-936a-454d-8146-9418c538eea0
relation.isAuthorOfPublicationbb8d007d-b8da-4e9b-a3cf-d20d256f1af8
relation.isAuthorOfPublicationd9ab10bc-ed17-4df2-9efc-90a3e2d0852a
relation.isAuthorOfPublication12713ef8-93ac-4f13-86f4-5d74d0497914
relation.isAuthorOfPublicationec6f464c-28e1-4b11-aa21-dfbad8ad3d79
relation.isAuthorOfPublication3460e4e6-bb4b-4ed2-a2d2-b4a778db0e9e
relation.isAuthorOfPublication.latestForDiscoveryd9ab10bc-ed17-4df2-9efc-90a3e2d0852a

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Indoor Air Quality and Sustainability Management_Post-print.pdf
Size:
871.91 KB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: