Impacto das lupas de magnificação nas linhas de terminação dos preparos para prótese fixa

datacite.subject.fosCiências Médicas::Medicina Clínicapt_PT
dc.contributor.advisorRibeiro, Paulo Soares
dc.contributor.advisorCarvalho, Alexandrine
dc.contributor.authorLobão, Catarina Nóbrega
dc.date.accessioned2023-09-22T11:24:02Z
dc.date.available2023-09-22T11:24:02Z
dc.date.issued2023-07-26
dc.description.abstractObjetivo: O objetivo deste estudo foi determinar qual o impacto das lupas de magnificação na qualidade das linhas de terminação durante a realização dos preparos para prótese fixa. Métodos: Foram utilizados 64 dentes naturais, divididos de forma equitativa, em 2 Grupos (O e L), consoante foram preparados a olho nú ou com lupas de magnificação 2,5x. Foram definidos 3 critérios de avaliação (Continuidade, Rugosidade e Espessura) que visaram determinar, com objetividade, a qualidade da linha de terminação dos preparos dentários para prótese fixa. Esta avaliação foi feita recorrendo a um microscópio odontológico de ampliação 10x. A concordância inter e intrainvestigador foi também avaliada. Resultados: Não existiram diferenças significativas entre o Grupo O e L em nenhum dos parâmetros avaliados. Na Espessura, o Grupo O apresenta uma mediana (AIQ) de 600 μm (500; 800μm) e o Grupo L de 600 μm (400; 800 μm). O Grupo L mostrou-se Contínuo em 64,8% dos casos, Pouco Contínuo em 26,1% e Não Contínuo em 9,1% das avaliações, tendo assim uma ligeira vantagem em relação ao Grupo O, cujos valores eram 58,0%, 35,2% e 6,8% respetivamente. O Grupo L apresentou-se Polido em 71,0% dos casos e Rugoso em 29,0% dos casos, contra 69,3% e 30,7% do Grupo O pela mesma ordem. Conclusões: As lupas de magnificação 2,5x demonstraram um curto impacto positivo na melhoria da qualidade dos preparos dentários para prótese fixa, no entanto, como os resultados não são Estatisticamente significativos para a amostra, está impossibilitada a sua extrapolação para a população.pt_PT
dc.description.abstractObjective: The aim of this study was to determine the impact of magnifying loupes on the quality of the finish lines during the dental preparation of fixed prosthesis. Methods: A total of 64 natural teeth were used, divided into 2 groups (O and L), equally distributed according to whether the teeth were prepared with the naked eye or with a 2.5x magnifying loupes, respectively. Three evaluation criteria (Continuity, Roughness, Thickness) were defined in order to objectively determine the quality of the finish line of the dental preparations for fixed prosthesis. This evaluation was done using a dental microscope with 10x magnification. Inter and intra-investigator agreement was also evaluated. Results: There were no significant differences between the groups in any of the parameters evaluated. In thickness, Group O had a median (IQR) of 600 μm (500; 800μm) and Group L, 600 μm (400; 800 μm). Group L was Continuous in 64.8% of the cases, Slightly Continuous in 26.1% of the evaluations, and Not Continuous in 9.1% of the cases, thus having a slight advantage over Group O, whose values were 58.0%, 35.2%, and 6.8% respectively. Group L was polished in 71.0% of the cases and rough in 29.0% of the evaluations, against 69.3% and 30.7% of Group O, subsequently. Conclusions: The 2.5x magnification showed a short positive impact in improving the quality of the finish line, however, as the results are not statistically significant for the sample, it is impossible to extrapolate them to the population.pt_PT
dc.identifier.tid203536681
dc.identifier.urihttp://hdl.handle.net/10284/12075
dc.language.isoporpt_PT
dc.subjectPrótese fixapt_PT
dc.subjectLupas de magnificaçãopt_PT
dc.subjectLinha de terminaçãopt_PT
dc.subjectPreparação dentáriapt_PT
dc.subjectQualidade de preparaçãopt_PT
dc.subjectFixed prosthesispt_PT
dc.subjectMagnification loupespt_PT
dc.subjectFinish linept_PT
dc.subjectDental preparationpt_PT
dc.subjectPreparation qualitypt_PT
dc.titleImpacto das lupas de magnificação nas linhas de terminação dos preparos para prótese fixapt_PT
dc.typemaster thesis
dspace.entity.typePublication
rcaap.rightsopenAccesspt_PT
rcaap.typemasterThesispt_PT
thesis.degree.nameMestrado Integrado em Medicina Dentáriapt_PT

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
PPG_38325.pdf
Size:
1.12 MB
Format:
Adobe Portable Document Format
Description:
38325
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: