Publication
Eficácia da aplicação da técnica eletrólise percutânea intra-tecidular no tendão supraespinhoso
dc.contributor.advisor | Cervaens, Mariana | |
dc.contributor.advisor | Pereira, Marcelo | |
dc.contributor.author | Maia, Joana Dias de Carvalho Marques | |
dc.date.accessioned | 2022-01-07T10:26:43Z | |
dc.date.available | 2022-01-07T10:26:43Z | |
dc.date.issued | 2021 | |
dc.description | Projeto de Graduação apresentado à Universidade Fernando Pessoa como parte dos requisitos para obtenção do grau de Licenciada em Fisioterapia | pt_PT |
dc.description.abstract | Introdução: A tendinopatia do supraespinhoso é a patologia mais comum que atinge a coifa dos rotadores. Objetivo: Verificar a eficácia da técnica eletrólise percutânea intra-tecidular (EPI©) aliada aos exercícios excêntricos, quando comparada apenas aos exercícios excêntricos, na dor, funcionalidade e amplitude, em pacientes com tendinopatia do supraespinhoso. Metodologia: A amostra foi constituída por 12 pacientes das clínicas Fisioon – Fisioterapia & Saúde Integral e PhysioClinic, entre os 35 e os 79 anos, aos quais foram aplicados a Escala Numérica da Dor para avaliação subjetiva da dor, as escalas The Disabilities of the Arm, Shoulder and Hand Questionnaire, Shoulder Pain and Disability Index e American Shoulder and Elbow Surgeons para avaliação da funcionalidade do ombro e um goniómetro para avaliação das amplitudes articulares de movimento. Os participantes foram divididos por conveniência em dois grupos, o experimental, submetido ao tratamento com EPI© aliado a exercícios excêntricos e o controlo submetido apenas a exercícios excêntricos. Resultados: O grupo EPI apresentou melhorias significativas nas escalas aplicadas, dor em movimento e em três dos movimentos avaliados no ombro. No entanto, quando comparado com o grupo controlo não houve diferenças significativas em nenhuma variável. Conclusão: A intervenção terapêutica EPI© teve melhorias significativas na dor em movimento, funcionalidade e aumento de amplitude, mas não significativo quando comparado com o grupo de controlo. | pt_PT |
dc.description.abstract | Introduction: Supraspinatus tendinopathy is the most common pathology that affects the rotator cuff. Objective: Verify the efficacy of intratissue percutaneous electrolysis (EPI©) associated with eccentric exercise when compared to the individual application of eccentric exercises in pain, function and range of motion, in patients with supraspinatus tendinopathy. Methodology: The sample consisted of 12 patients from the Fisioon – Fisioterapia & Saúde Integral e PhysioClinic, between 35 and 79 years old, to whom was applied the Numeric Pain Rating Scale (NPRS) for subjective pain assessment, The Disabilities of the Arm, Shoulder and Hand Questionnaire, Shoulder Pain and Disability Index e American Shoulder and Elbow Surgeons scales to assess shoulder functionality and a goniometer to assess joint range of motion. Participants were conveniently divided into two groups, experimental which was submitted to EPI© combined with eccentric exercises and the control group to whom was applied only eccentric exercises. Results: The EPI© group showed significant improvements on the applied scales, pain in motion and in three of the movements evaluated in the shoulder. However, when compared to the control group there was no significant improvement in any of the variables. Conclusion: The therapeutic intervention EPI© originated significant improvement on pain in motion, functionality and better range of motion but insignificant when compared to the control group. | pt_PT |
dc.description.version | N/A | pt_PT |
dc.identifier.uri | http://hdl.handle.net/10284/10598 | |
dc.language.iso | por | pt_PT |
dc.subject | Electrólise percutânea | pt_PT |
dc.subject | Exercício excêntrico | pt_PT |
dc.subject | Dor | pt_PT |
dc.subject | Funcionalidade | pt_PT |
dc.subject | Amplitude | pt_PT |
dc.subject | Tendinopatia | pt_PT |
dc.subject | Percutaneous electrolysis | pt_PT |
dc.subject | Eccentric exercise | pt_PT |
dc.subject | Pain | pt_PT |
dc.subject | Functionality | pt_PT |
dc.subject | Range of motion | pt_PT |
dc.subject | Tendinopathy | pt_PT |
dc.title | Eficácia da aplicação da técnica eletrólise percutânea intra-tecidular no tendão supraespinhoso | pt_PT |
dc.type | bachelor thesis | |
dspace.entity.type | Publication | |
rcaap.rights | openAccess | pt_PT |
rcaap.type | bachelorThesis | pt_PT |
Files
Original bundle
1 - 1 of 1
Loading...
- Name:
- PG_36207.pdf
- Size:
- 319.17 KB
- Format:
- Adobe Portable Document Format
- Description:
- PG_36207