Repository logo
 
Publication

Multi-Mode adhesives performance and success/retention rates in NCCLs restorations: randomised clinical trial one-year report

dc.contributor.authorManarte-Monteiro, Patricia
dc.contributor.authorDomingues, Joana
dc.contributor.authorTeixeira, Liliana
dc.contributor.authorGavinha, Sandra
dc.contributor.authorManso, Maria Conceição
dc.date.accessioned2019-11-18T08:32:56Z
dc.date.available2019-11-18T08:32:56Z
dc.date.issued2019-09-23
dc.description.abstractAim: Compare clinical performance and success/retention rates of two multi-mode (MM) adhesives, applied in self-etch (SE) or etch-and-rinse (ER) modes, with SE-all-in-one adhesive (SE/SE with enamel etching) in NCCL restorations at one-year follow-up. Material and methods: Prospective, double-blind RCT approved by the University Fernando Pessoa and the National-Clinical-Research-Ethics Committees (CEIC-20150305), ClinicalTrials.gov registered (NCT02698371), in 38 participants with 210 restorations (AdmiraFusionVR ) randomly allocated to six groups (Adhesives_Adhesion mode), each with 35 restorations: G1-Control FuturabondVRDC_SE; G2-Control FuturabondVRDC_SE with enamel etching; G3-FuturabondVRU_ER; G4-FuturabondVR U_SE; G5-AdheseVR Universal_ER; G6-AdheseVR Universal_SE. Restorations evaluated at baseline and one-year by three calibrated examiners (ICC 0.952) using FDI criteria and statistical analysis with nonparametric tests (alpha=0.05). Results: At one-year recall 36 participants, 199 restorations were available for examination; five (2.5%) restorations (G1 n=2; G2, G3, G4 n=1) were lost due to retention (p>.05); G1 showed less satisfying marginal adaptation (p<.05) than G2 and MM adhesives groups, particularly G6. Overall success rates (p>.05) were: 93.9% (G1), 97.0% (G2; G3; G4) and 100.0% (G5; G6). Conclusions: MM adhesives (FuturabondVRU and AdheseVR Universal) showed similar and acceptable performance/success rates but also better clinical outputs than the SE-all-in-one adhesive (FuturabondVR DC), particularly in SE mode. Success and retention rates were similar and not dependent on materials or adhesion modes.pt_PT
dc.description.sponsorshipFundacão Fernando Pessoa, Porto, Portugalpt_PT
dc.description.versioninfo:eu-repo/semantics/publishedVersionpt_PT
dc.identifier.citationPatrícia Manarte-Monteiro, Joana Domingues, Liliana Teixeira, Sandra Gavinha & Maria Conceição Manso (2019) Multi-Mode adhesives performance and success/ retention rates in NCCLs restorations: randomised clinical trial one-year report, Biomaterial Investigations in Dentistry, 6:1, 43-53, DOI: 10.1080/26415275.2019.1684199pt_PT
dc.identifier.doi10.1080/26415275.2019.1684199pt_PT
dc.identifier.issn2641-5275
dc.identifier.urihttp://hdl.handle.net/10284/8230
dc.language.isoengpt_PT
dc.peerreviewedyespt_PT
dc.publisherTaylor & Francispt_PT
dc.relation.publisherversionhttps://www.tandfonline.com/doi/full/10.1080/26415275.2019.1684199pt_PT
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/pt_PT
dc.subjectMulti-mode adhesivespt_PT
dc.subjectAdhesion modept_PT
dc.subjectNon-carious cervical lesionpt_PT
dc.subjectRandomised clinical trialpt_PT
dc.titleMulti-Mode adhesives performance and success/retention rates in NCCLs restorations: randomised clinical trial one-year reportpt_PT
dc.typejournal article
dspace.entity.typePublication
oaire.citation.endPage53pt_PT
oaire.citation.issue1pt_PT
oaire.citation.startPage43pt_PT
oaire.citation.titleBiomaterial Investigations in Dentistrypt_PT
oaire.citation.volume6pt_PT
person.familyNameManarte-Monteiro
person.familyNameDomingues
person.familyNameTeixeira
person.familyNameGavinha
person.familyNameManso
person.givenNamePatricia
person.givenNameJoana
person.givenNameLiliana Alexandra Pascoal
person.givenNameSandra
person.givenNameMaria da Conceição
person.identifier1692297
person.identifier.ciencia-id0716-F859-4223
person.identifier.ciencia-id7F1B-ECE5-6CF7
person.identifier.ciencia-id0A14-1FF4-3383
person.identifier.ciencia-id5A18-502F-4844
person.identifier.orcid0000-0002-8821-1624
person.identifier.orcid0000-0001-6306-3736
person.identifier.orcid0000-0002-8028-8619
person.identifier.orcid0000-0002-2430-1241
person.identifier.orcid0000-0002-1774-1337
person.identifier.ridD-7212-2013
person.identifier.scopus-author-id55598215300
person.identifier.scopus-author-id35758590200
person.identifier.scopus-author-id57196702148
rcaap.rightsopenAccesspt_PT
rcaap.typearticlept_PT
relation.isAuthorOfPublication95c4bc89-8e54-47a9-acb6-82801f3b4204
relation.isAuthorOfPublication211ed2b9-8fd6-4948-9962-d2f84a8c5572
relation.isAuthorOfPublication0154c07e-c7ca-4836-8899-551f39e4b8b4
relation.isAuthorOfPublication06781d5e-f4bb-4d28-9234-c376a64a1edc
relation.isAuthorOfPublication7dff8d33-6bfb-496b-b734-a94146c562e6
relation.isAuthorOfPublication.latestForDiscovery06781d5e-f4bb-4d28-9234-c376a64a1edc

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Multi Mode adhesives performance and success retention rates in NCCLs restorations randomised clinical trial one year report.pdf
Size:
1.74 MB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: